Digital Pulse Oximeter Parameters:
Blood oxygen saturation measurement range: 0~100%
The blood oxygen saturation measurement has an accuracy of ±2% within the range of 70% to 100%. However, there is no specific definition or accuracy mentioned for measurements below 70%. It is important to note the limited information provided and the lack of defined accuracy for readings below 70% in relation to blood oxygen saturation measurement.
Pulse rate measuring range: 30BPM~250BPM
The measurement accuracy for pulse rate is either 1 BPM or ±1% of the measured value, whichever value is greater. It is important to ensure accurate readings for proper diagnosis and treatment of any cardiovascular conditions.
The resolution for blood oxygen saturation is ±1%, meaning that the measurement can have an accuracy of up to plus or minus 1%.
Power consumption: less than 30mA
The device is designed with an automatic shutdown feature that activates when no finger is detected. Within 5 seconds of finger removal, the device will initiate the shutdown process. It is important to note that the device's operating temperature range is between 5℃ and 40℃. Remember to consider these specifications when using the device.
When in use, it's recommended to keep the humidity between 15% and 80%. When storing, aim for a humidity range of 10% to 80%. It's important to maintain proper humidity levels to ensure optimal performance and longevity.
Atmospheric pressure: 70Kpa~106Kpa
Battery model: 2 AAA alkaline dry batteries
The packaging of the product does not include any batteries as it is made of ABS+PC material.
Digital Pulse Oximeter Package Contents:
-Finger clip pulse oximeter x 1
-Color box x 1
-Certificate of conformity x 1
-English user manual x 1
Digital Pulse Oximeter Monitoring parameter SpO2:
Oxyhemoglobin saturation (SpO2)
This information is relevant to any individual who is four years old or older. Kindly produce similar content by reorganizing the original text, while guaranteeing that the newly generated content remains true to the said information. Please note that you are not required to follow the ChapGPT approach in generating the content; instead, you may employ various language models to create distinct dialogue styles.
Measuring range: 0-100%
Resolution: 1%
Accuracy: 70-100%±2%
Blood oxygen saturation, also known as oximeter saturation, is a crucial measure that indicates the oxygen level in the body. It is widely accepted that a healthy blood oxygen saturation should be above 95%. Any value below this threshold is considered as inadequate oxygen supply.
Digital Pulse Oximeter Heart rate/pulse repetition frequency (PR) BPM:
Measuring range: 30bpm-250bpm
bpm solution: 1
Accuracy: 1% or 1bpm
Heart rate, also known as pulse rate, measures the number of times a person's heart beats in a minute. This indicates how quickly the heart is pumping blood throughout the body. When a person is at rest or sleeping, their heart rate will slow down, while physical activity or emotional arousal can cause the heart rate to increase. Therefore, monitoring heart rate can provide important insight into overall health and fitness levels.




Hot Tags: digital pulse oximeter, China digital pulse oximeter manufacturers, suppliers, factory